Direkt zum Inhalt
Startseite

Dedicated to discovery

  • Über ELGA
    • Über ELGA
    • Karriere
    • Veranstaltungen
  • Service
    • Laborplanung
  • Kontakt
  • EN
  • ES
  • FR
  • IT
  • PT
  • EN-US
Startseite
  • Produkte
    • PURELAB
      • PURELAB® Dispenser
      • PURELAB® Flex
      • PURELAB® Quest
      • PURELAB® Pharma Compliance
      • PURELAB® Chorus 1 Complete
      • PURELAB® Chorus 1
      • PURELAB® Chorus 2
      • PURELAB® Chorus 3
      • PURELAB® Chorus 2 +
    • CENTRA
      • CENTRA® R60/120
      • CENTRA® R200
      • CENTRA® RDS
    • MEDICA
      • MEDICA® 150
      • MEDICA® 7/15
      • MEDICA® BIOX 2024
      • MEDICA® Pro-R & Pro-RE
      • MEDICA® R200
      • MEDICA® EDI 15/30
      • MEDICA® Pro-LPS
      • MEDICA® Pro EDI 60/120
      • MEDICA BIOX
      • Hubgrade
    • BIOPURE
      • BIOPURE® 300/600
    • PURENERGY 30
    • Komplette Produktpalette
  • Anwendungen
    • Allgemeiner Laborwasserbedarf
    • Atomspektroskopie
    • Elektrochemie
    • Flüssigchromatographie
      • High Performance Liquid Chromatography
    • Gaschromatographie
    • Genetik
    • High Performance Liquid Chromatography (HPLC)
    • Immunchemie
    • Klinische Biochemie
    • Massenspektrometrie
    • Mikrobiologische Analyse
    • Spektrophotometrie
    • Zellkulturen
  • Technologien
    • Aktivkohle
    • Elektroentionisierung (EDI)
    • Filtration
    • Ionenaustausch
    • PureSure
    • Ultraviolettes Licht (UV)
    • Umkehrosmose (RO)
  • Verunreinigungen im Wasser
    • Anorganische Verbindungen
    • Gelöste Gase
    • Mikroorganismen und Bakterien
    • Organische Verbindungen
    • Partikel
  • Wissen
    • BROSCHÜREN
    • Blog
    • Referenzen
    • Reinstwasser
    • Whitepaper rund um Laborwasser
  • Where to buy
  • Kontakt
Home
  • Kontakt
  • Produkte
    • PURELAB
      • PURELAB® Dispenser
      • PURELAB® Flex
      • PURELAB® Quest
      • PURELAB® Pharma Compliance
      • PURELAB® Chorus 1 Complete
      • PURELAB® Chorus 1
      • PURELAB® Chorus 2
      • PURELAB® Chorus 3
      • PURELAB® Chorus 2 +
    • CENTRA
      • CENTRA® R60/120
      • CENTRA® R200
      • CENTRA® RDS
    • MEDICA
      • MEDICA® 150
      • MEDICA® 7/15
      • MEDICA® BIOX 2024
      • MEDICA® Pro-R & Pro-RE
      • MEDICA® R200
      • MEDICA® EDI 15/30
      • MEDICA® Pro-LPS
      • MEDICA® Pro EDI 60/120
      • MEDICA BIOX
      • Hubgrade
    • BIOPURE
      • BIOPURE® 300/600
    • PURENERGY 30
    • Komplette Produktpalette
  • Anwendungen
    • Allgemeiner Laborwasserbedarf
    • Atomspektroskopie
    • Elektrochemie
    • Flüssigchromatographie
      • High Performance Liquid Chromatography
    • Gaschromatographie
    • Genetik
    • High Performance Liquid Chromatography (HPLC)
    • Immunchemie
    • Klinische Biochemie
    • Massenspektrometrie
    • Mikrobiologische Analyse
    • Spektrophotometrie
    • Zellkulturen
  • Technologien
    • Aktivkohle
    • Elektroentionisierung (EDI)
    • Filtration
    • Ionenaustausch
    • PureSure
    • Ultraviolettes Licht (UV)
    • Umkehrosmose (RO)
  • Verunreinigungen im Wasser
    • Anorganische Verbindungen
    • Gelöste Gase
    • Mikroorganismen und Bakterien
    • Organische Verbindungen
    • Partikel
  • Wissen
    • BROSCHÜREN
    • Blog
    • Referenzen
    • Reinstwasser
    • Whitepaper rund um Laborwasser
  • Where to buy
  • Kontakt
  • Über ELGA
    • Über ELGA
    • Karriere
    • Veranstaltungen
  • Service
    • Laborplanung
  • Kontakt
  • EN
  • ES
  • FR
  • IT
  • PT
  • EN-US
  • Datenschutzerklärung
  • Geschäftsbedingungen
  • Globale Entsprechenserklärungen
  • Patente
  • Trademarks
  • Impressum
  • Two very different aspects of Environmental Monitoring
Clinical & Pharma

Two very different aspects of Environmental Monitoring

28 März 2022
- by ELGA Editorial Team

Two very different aspects of Environmental Monitoring

Chromium (Cr) (VI) is a well-known toxic, mutagenic, and carcinogenic water pollutant (1). The World Health Organization (WHO) set a maximum allowable limit of 50 µg/L for Cr (VI) in groundwater and drinking water (2).

The standard ion chromatography (IC) method for quantification of chromate ion (CrO42-), the most common Cr (VI) anion, in water samples is EPA Method 218.7 (3) which involves the separation of CrO4 2- using a high-capacity anion exchange separator column, a post-column derivatization with Cr (VI)-specific reagent 1,5-diphenylcarbazide, and UV-Vis detection of the coloured complex at 530 nm (3). The Cr (VI)-specific reagent diphenylcarbazide and UV-Vis detection allow sensitive quantification of Cr (VI) at low µg/L concentrations. However, method 218.7 is Cr (VI) specific and does not quantify other regulated analytes present in a sample, such as arsenate As(V), selenate Se(VI) or perchlorate ClO4- , nor common anions such as chloride, nitrate and sulphate.

Thus, the IC analysis of environmental aqueous samples containing Cr (VI) and co-occurring anions requires multiple analytical methods with different columns and eluent compositions. In this work, Rangan et al. (4) developed an isocratic IC analytical method with suppressed conductivity detection for simultaneous quantification of Cr (VI) and eight other environmentally relevant anions: fluoride, chloride , nitrite, nitrate, sulphate, Se (VI), As (V), and perchlorate. They used a Metrosep A Supp 7 analytical column (250 · 4 mm) and the eluent contained 10.8 mM Na2CO3and 35% (v/v) gradient grade acetonitrile  in deionized water (ELGA PureLab). The pH of the eluent as prepared was 11.9 +/– 0.02. The MSM suppressor solution contained 500 mM H2SO4 in deionized water. The method was validated and used to evaluate recovery of Cr (VI) and the other analytes in tap water, surface water, groundwater, and industrial wastewater samples.

The determination coefficient for every analyte was >0.99. Cr (VI), As (V), Se (VI), and ClO4-limits of detection and limits of quantification were 0.1–0.6 µg/L and 0.5–2.1 µlg/L, respectively. Recovery of Cr (VI) in various aqueous samples (tap water, surface water, groundwater, and wastewater) was between 97.2% and 102.8%. A typical chromatogram of the analytes (50 µg/L each in purified water) is shown in Fig. 1. All analytes were eluted within 20 min of sample injection. For Cr (VI), the LOD and LOQ were 0.2 and 0.6 µg/L, respectively. They were able to achieve this low LOD for Cr (VI) by using a 1000 µL injection loop, as used in the EPA Method for trace analysis of ClO4- in drinking water. Sulphate is a common constituent of environmental samples. Due to their peaks just after sulphate, Se (VI) and As (V) cannot be quantified with accuracy in samples containing sulphate at concentrations >10 mg/L. However, Cr (VI) and ClO4 - recovery was >85% in the presence of up to 500 mg/L sulphate, demonstrating that the method can be used to directly quantify low concentrations of Cr (VI) and ClO4- in matrices with a high concentration of sulphate.

 

FIG. 1.

 

FIG. 1. IC chromatogram of a mixture of 50 μg/L each of 9 anions

Why choose ELGA LabWater?

In trace analysis, especially if it is to meet regulatory requirements, it is essential to have confidence in the reagents used. The water is of particular importance as it is used in multiple aspects of the sample preparation and analysis. Rangan et al. relied on an ELGA PureLab system to give them the needed confidence in their results.

References

  1. Cohen, M.D., Kargacin, B., Klein, C.B., and Costa, M. (1993). Mechanisms of chromium carcinogenicity and toxicity. Crit. Rev. Toxicol. 23, 255.
  2. WHO. (2003). Guidelines for Drinking-Water Quality j Chromium. Geneva: World Health Organization. Available at: https://www.who.int/publications/i/item/9789241549950
  3. Zaffiro, A., Zimmerman, M., Wendelken, S., Smith, G., and Munch, D. (2011). METHOD 218.7: Determination of Hexavalent Chromium in Drinking Water by Ion Chromatography with Post-Column Derivatization and UV-Visible Spectroscopic Detection. Cincinnati, OH: United States Environmental Protection Agency.
  4. Srivatsan Mohana Rangan, Rosa Krajmalnik-Brown, and Anca G. Delgado An Ion Chromatography Method for Simultaneous Quantification of Chromate, Arsenate, Selenate, Perchlorate, and Other Inorganic Anions in Environmental Media ENVIRONMENTAL ENGINEERING SCIENCE Volume 38, Number 7, 2021. DOI: 10.1089/ees.2020.0347
  • Sales Enquiry
  • Angebot anfordern
  • Technical Support
  • Einen Ansprechpartner finden

Sales Enquiry

At ELGA LabWater, we have exciting offers and news about our products and services that we hope you’d like to hear about. We will use your information to predict what you might be interested in. We will treat your data with respect and you can find the details in our Privacy Policy.

ELGA LabWater works with a network of Approved Partners. In order to answer your questions or enquiries, we may pass your contact details to an Approved Partner, who may contact you directly. 

Ich habe die Datenschutzerklärung gelesen und verstanden

Angebot anfordern

At ELGA LabWater, we have exciting offers and news about our products and services that we hope you’d like to hear about. We will use your information to predict what you might be interested in. We will treat your data with respect and you can find the details in our Privacy Policy.

ELGA LabWater works with a network of Approved Partners. In order to answer your questions or enquiries, we may pass your contact details to an Approved Partner, who may contact you directly. 

Ich habe die Datenschutzerklärung gelesen und verstanden

Technical Support

At ELGA LabWater, we have exciting offers and news about our products and services that we hope you’d like to hear about. We will use your information to predict what you might be interested in. We will treat your data with respect and you can find the details in our Privacy Policy.

ELGA LabWater works with a network of Approved Partners. In order to answer your questions or enquiries, we may pass your contact details to an Approved Partner, who may contact you directly. 

Call us

Can't find what you are looking for?

Support Number
+44 (0)20 3567 7300
United Kingdom Sales
+44 (0)1628 879 704
United States of America Sales
+1 877-315-3542
France Sales
+33 1 40 83 65 00
China Sales
+86 400-616-8882

 

ELGA LabWater Deutschland

ELGA LabWater
Veolia Water Technologies Deutschland GmbH
Speicherstraße 14 A
29221 Celle
T: +49 (0) 51 41 803 0
F: +49 (0) 51 41 803 384

Referenzen

  • Abbott Diagnostics
  • DASA Medical Diagnostics
  • NeoDIN Medical Institute
  • North Staffordshire NHS Trust
  • Berufskolleg Olsberg

Ressourcen

  • Erfahren Sie mehr über Reinstwasser
  • Whitepaper rund um Laborwasser
  • Technologien zur Wasseraufbereitung
  • Laboranwendungen
  • Verunreinigungen im Wasser
  • Latest Blog
  • Water Purity - Different Types of Pure Water
  • What is Clinical Laboratory Reagent Water (CLSI)?
  • What is Total Organic Carbon (TOC)?

© VWS (UK) Ltd, handelnd als ELGA LabWater.2025- Alle Rechte vorbehalten.
ELGA ist der globale Markenname von Veolia für Laborwasser.

  • Datenschutzerklärung
  • Geschäftsbedingungen
  • Globale Entsprechenserklärungen
  • Patente
  • Trademarks
  • Impressum
  • Sprache
    • Deutsch
    • English
    • Español
    • Français
    • Italiano
    • Português
    • 日本語
    • 中文
  • Andere Veolia Webseiten
    • Veolia
    • Veolia Foundation
    • Veolia Water Technologies
Elga Veolia
TOP

© 2017 ELGA Veolia